mcq on voltage regulator and power supply

Share this

0%
0 votes, 0 avg
Created on

DC Power supply

Regulated DC power supply MCQ

dc power supply mcq

tail spin

1 / 56

1.

Which transformer increases the voltage?

2 / 56

2. The maximum rectification efficiency of bridge full-wave rectifier is around

3 / 56

3. The maximum rectification efficiency of the center tapped full-wave rectifier is

4 / 56

4. A power supply which has voltage regulation of ……….. is unregulated power supply

5 / 56

5. An ideal regulated power supply is one which has voltage regulation of …………

6 / 56

6. The diode is a _______ device

7 / 56

7. Which filter reduces the ripple?

8 / 56

8. The output obtained by the rectifier is

9 / 56

9. filter is used to obtain DC voltage with some ripple

10 / 56

10. A power supply has a voltage regulation of 1%. If the no-load  voltage is 20 V, what is the full-load voltage?

11 / 56

11. The disadvantages of linear DC power supply are

12 / 56

12. Which transformer is used in a regulated DC power supply?

13 / 56

13. For increasing the voltage rating, zeners are connected in …………..

14 / 56

14. The unregulated power supply used in 

15 / 56

15. How many types of regulated power supplies are there?

Hint

  1. Adjustable voltage regulator
  2. Zener diode regulators
  3. Current limiters
  4. Series regulators

16 / 56

16. The Zener current will be minimum when …………

17 / 56

17. allows DC but it blocks AC

18 / 56

18. Output of a phase splitter is

19 / 56

19. The maximum rectification efficiency of half-wave rectifier is around

20 / 56

20. The output voltage of a switch-mode power supply is

21 / 56

21. The switch-mode power supply categorized into

Hint

  1. AC in DC out
  2. DC in DC out
  3. DC in AC out
  4. AC in AC out

22 / 56

22. The AC component present in output voltage is called

23 / 56

23. are the building blocks of regulated DC power supply

24 / 56

24. The rectifiers are categorized into

Half wave and Full wave rectifier

25 / 56

25. The transient response of linear power supply is around

26 / 56

26. The Zener current is maximum when the load current is

27 / 56

27. A regulated DC power supply is also known as

28 / 56

28. In an unregulated power supply, if input a.c. voltage increases, the output voltage …….

29 / 56

29. Two similar 15 V Zeners are connected in series. What is the regulated output voltage?

30 / 56

30. If the load current drawn by unregulated power supply increases, the d.c. output voltage ………..

31 / 56

31. ..............rectifiers are full-wave rectifiers 

32 / 56

32. In a Zener voltage regulator, the changes in load current produce changes in …………….

33 / 56

33. The rectification is a process of converting.............

34 / 56

34. The output of the rectification is ................

35 / 56

35. Commercial power supplies have voltage regulation ………….

36 / 56

36. How many diodes does bridge full-wave rectifier consists

37 / 56

37. Regulated power supplies are used in ..................

38 / 56

38. The input voltage range of linear power supply is around

39 / 56

39. The noise of the switching DC power supply is 

40 / 56

40. The hold-up time of linear power supply is around

41 / 56

41. The ripple factor of the center tapped full-wave rectifier is

42 / 56

42. The efficiency of linear power supply is around

43 / 56

43. If the load current drawn by unregulated power supply increases, the d.c. output voltage ………

44 / 56

44. In switch-mode power supply the regulation of voltage is done by controlling

45 / 56

45. Rectification can be done by using 

46 / 56

46. How many diodes does the center tapped full wave rectifier consists of?

47 / 56

47. A Zener regulator …………… in the power supply

48 / 56

48. How many diodes does half-wave rectifier consists of

49 / 56

49. The advantages of linear DC power supply are

50 / 56

50.  If the load resistance decreases in a Zener regulator, then Zener current …………….

51 / 56

51. In an unregulated power supply, if load current increases, the output voltage ………..

52 / 56

52. The ripple factor of half-wave rectifier is

53 / 56

53. The load regulation of the switching DC power supply is

54 / 56

54. When load current is zero, the Zener current will be ………

55 / 56

55. Zener diode can be used as …………

56 / 56

56. The input linear filter is required in

Your score is

The average score is 23%

0%

Exit

Thank you

Share this

Leave a Comment

Your email address will not be published. Required fields are marked *